If you’re working with liquid silicone rubber (LSR) or other silicone materials in manufacturing, you know that pressure control isn’t just a technical detail—it’s the difference between smooth, consistent parts and costly defects like flashing, incomplete filling, or material degradation. As a silicone machine supplier, I get questions about this all the time: “How do you actually control pressure on these machines, and why does it matter so much for silicone work?” Today, I’m breaking down the real, practical pressure control methods we use on our equipment, tailored specifically to the unique properties of silicone materials.
First, let’s ground this in what makes silicone different from other plastics. LSR is a two-part, platinum-cured material with a very low viscosity when mixed, which means it flows easily—but it also starts curing (cross-linking) almost as soon as the parts are mixed. That means pressure control needs to balance two competing needs: getting the material into every detail of the mold before it cures, and not applying so much pressure that it forces excess material out (flashing) or damages delicate mold components. That’s why our approach to pressure control isn’t one-size-fits-all; it’s a multi-stage system built around three core pressure zones: plasticating, injection, and holding.
Let’s start with plasticating pressure, which is the pressure applied to the LSR material as it’s mixed and fed into the injection unit. LSR comes in two separate cartridges, typically Part A and Part B, that are pumped into the machine’s mixing chamber just before injection. If the plasticating pressure is too low, the two parts won’t mix thoroughly—leading to inconsistent cure rates and soft or brittle parts. If it’s too high, the material can shear excessively during mixing, which generates heat and can prematurely cure the LSR in the barrel, causing blockages or uneven material flow.
This is where our machine design makes a tangible difference. For example, our TYM-W Toggle LSR Injection Molding Machine uses a closed-loop hydraulic system for plasticating pressure control. What that means in plain terms is that we have a pressure sensor mounted right on the mixing barrel that sends real-time data to the machine’s control panel. If the pressure drifts even 5% from the setpoint, the system adjusts the feed rate of the LSR cartridges or the speed of the mixing screw to correct it automatically. No more manual adjustments that lead to inconsistent mixes—this is a big reason many of our clients switch from older, less precise machines for high-volume LSR parts like medical seals or consumer electronics gaskets.
Next is injection pressure, which is the force used to push the mixed LSR from the barrel into the closed mold. This is the most critical stage because it directly impacts how well the material fills the mold cavity. Silicone’s low viscosity means it can fill very fine details, but only if the injection pressure is calibrated correctly. For parts with thin walls (like a 0.5mm medical diaphragm), you need higher injection pressure to push the LSR into every crevice, but you have to stop before the mold’s venting system gets overwhelmed. For thicker parts, too much injection pressure can cause the material to move too quickly, trapping air bubbles that turn into voids after curing.


Our approach here is modular, which is why our TYM-W LSR Injection Molding Machine stands out. The control panel lets users set up to 10 distinct injection pressure stages, each with its own pressure and speed. For example, a typical cycle might start with low pressure and slow speed to avoid pushing air into the mold, ramp up pressure to fill 90% of the cavity, then drop to a lower pressure for the final 10% to prevent flashing. This staged approach isn’t just a theoretical win—we’ve worked with a automotive client that used our machine to cut their defect rate for silicone engine gaskets by 18% after switching from a single-pressure injection system. They used to have to manually adjust pressure every 500 cycles, but the closed-loop control on our TYM-W machine keeps injection pressure consistent across thousands of parts.
The third key pressure zone is holding pressure, which is applied after the mold is full to compensate for the LSR material’s slight shrinkage as it cures. Silicone shrinks about 2-5% during vulcanization (the curing process in the mold), so without holding pressure, parts can develop sink marks or pull away from the mold walls, leading to dimensional inaccuracies. The tricky part with holding pressure is that it has to be high enough to prevent shrinkage, but low enough that it doesn’t force excess material out through the mold’s flash gaps.
This is where things get even more tailored, especially for multi-component silicone parts. If you’re making a part that combines LSR with hard plastic inserts (like a medical syringe plunger with a silicone seal), holding pressure becomes even more critical because the plastic insert expands differently than the silicone when heated. Our TYM-W55T200 2K / Double-Color Machine is designed specifically for these applications, with independent holding pressure controls for each material. That means you can set a different holding pressure for the hard plastic component and the silicone component, so neither one gets damaged or distorted during the curing phase. A dental supply client used this feature to produce a line of dual-material impression trays, cutting their rework rate by 22% because they no longer had parts where the silicone seal pulled away from the plastic base.
But pressure control isn’t just about machine settings—it’s also integrated with the mold and material. We always recommend that our clients work with mold makers who design vents tailored to silicone’s flow rate. If vents are too small, pressure can spike during injection; too large, and you get flashing. We also provide material-specific guidelines for pressure settings because different LSR formulations (hardness, viscosity, cure speed) need different pressure profiles. For example, a Shore A 30 LSR (soft, flexible) will need a lower injection pressure than a Shore A 70 LSR (firm, rigid), because the stiffer material flows less easily.
One common mistake we see new silicone manufacturers make is relying on static pressure settings, or only adjusting pressure when defects appear. That’s why our machines come with built-in data logging that tracks pressure at every stage of the cycle, so you can spot trends before they become problems. For example, if plasticating pressure starts increasing over time, that’s a sign that the mixing barrel is building up cured material residue, which needs to be cleaned. If injection pressure gradually decreases, that could mean the LSR cartridges are running low, or the feed line is clogged. The data logging feature also makes it easy to replicate successful cycles across shifts or production lines, which is a huge help for high-volume manufacturing.
Another question we get is about how our pressure control systems compare to pneumatic vs. hydraulic setups. A lot of older silicone machines use pneumatic pressure control, which is cheaper but less precise. Hydraulic systems, like the ones we use on our TYM-W line, offer much finer control (down to 0.1 bar of pressure adjustment) which is essential for small, complex parts. Some newer machines use all-electric pressure control, but we’ve found that for LSR, hydraulic systems still offer more consistent performance over long production runs, especially when running 24/7 for months at a time. We do offer hybrid options for clients who need higher energy efficiency, though—our TYM-W machines have energy-saving hydraulic pumps that only use power when adjusting pressure, so you get precision without the high energy costs.
At the end of the day, the goal of pressure control for silicone machines is to balance precision, speed, and material properties. You don’t want to sacrifice cycle time because you’re over-adjusting pressure, but you also can’t let defects eat into your profit margins. As a supplier, our job isn’t just to sell a machine—it’s to provide the tools and support to make sure our clients get consistent, high-quality parts every time. That’s why we include on-site training for every client, so their operators understand how to adjust pressure settings for their specific parts and materials, plus 24/7 technical support if they run into issues.
If you’re in the market for a silicone machine and want to learn more about how our pressure control systems can work for your production needs, we’re here to help. Whether you’re making small medical components, automotive gaskets, or consumer silicone goods, we can walk you through the options and help you find the right machine for your requirements.
References
- Rosato, D. V., & Rosato, M. G. (2012). Injection Molding Handbook (3rd ed.). Hanser Publications.
- Titomanlio, G., & Speranza, V. (2018). Pressure control in injection molding of thermosetting polymers. Journal of Polymer Engineering, 38(7), 621-634.
- International Organization for Standardization. (2020). ISO 10993-1: Biological evaluation of medical devices – Part 1: Evaluation and testing within a risk management process. ISO.
- Manufacturing Engineering Society International. (2021). Advances in liquid silicone rubber processing and equipment. Procedia Manufacturing, 53, 217-224.